АМ Type
АМ Type і is aluminum round soft wire.
Nominal diameter: from 1.60 to 9.50 mm.
Application: wire is used for manufacturing winding wires, cables and other electrical purposes.
АПТ Type
АПТ Type і is aluminum round semisolid wire.
Nominal diameter: from 1.60 to 9.50 mm.
Application: wire is used for manufacturing winding wires, cables and other electrical purposes.
АТ Type
АТ Type і is aluminum round solid wire.
Nominal diameter: from 1.60 to 9.50 mm.
Application: wire is used for manufacturing winding wires, cables and other electrical purposes.
Technical parameters of АТ, АМ, АПТ wire:
| Nominal wire diameter, mm | Tensile strength not less than, MPa | Relative elongation not less than, % | ||||
|---|---|---|---|---|---|---|
| АТ | АТП | АМ | АТ | АПТ | АМ | |
| from 1.60 to 2.50 | 167 | 88×137 | 74×98 | 1,3 | 2,0 | 20 |
| from 2,50 to 4,00 | 162 | 1,5 | 3,0 | |||
| from 4,00 to 5,00 | 157 | 2,0 | 2,5 | |||
| from 5,00 to 9,50 | 147 | |||||
ММ Type
ММ Type і is copper round soft wire.
Nominal diameter: from 0.30 to 9.00 mm.
Application: wire is used for manufacturing winding wires, cables and other electrical purposes.
МТ Type
МТ Type і is copper round solid wire.
Nominal diameter: from 0.30 to 9.00 mm.
Application: wire is used for manufacturing winding wires, cables and other electrical purposes.
Technical parameters of MT, MM wires:
| Nominal wire diameter, mm | Tensile strength not less than, MPa | Relative elongation not less than, % |
|---|---|---|
| МТ | ММ | |
| from 0,30 to 0,58 | 422 | 20 |
| above 0,58 to 0,97 | 422 | 25 |
| above 0,97 to 3,00 | 422 | 30 |
| above 3,00 to 5,00 | 392 | 30 |
| above 5,00 | 373 | 35 |
ПАМ Type
ПАМ Type і is aluminum rectangular soft wire.
Nominal wire dimensions: from 1,80×3,35 to 5,60×18,0 mm
Application: wire is used for manufacturing winding wires, cables and other electrical purposes.
ПАТ Type
ПАТ Type і is aluminum rectangular solid wire.
Nominal wire dimensions: from 1,80×3,35 to 5,60×18,0 mm.
Application: проволока предназначена для изготовления обмоточных проводов, кабелей и других электротехнических целей.
Technical parameters of ПАТ, ПАМ wire:
| Nominal wire cross-section, mm | Tensile strength not less than, MPa | Relative elongation not less than, % | ||
|---|---|---|---|---|
| ПАТ | ПАМ | ПАТ | ПАМ | |
| up to 30 | 130 | 70 | 1,5 | 25 |
| above 30 | 122 | 68,6 | 2,0 | 26 |
ПММ Type
ПММ Type і is copper rectangular soft wire.
Nominal wire dimensions: from 1,00×2,00 to 5,60×19,50 mm
Application: wire is used for manufacturing winding wires, cables and other electrical purposes.
ПМТ Type
ПМТ Type і is copper rectangular solid wire.
Nominal wire dimensions: from 1,00×2,00 to 5,60×19,50 mm.
Application: wire is used for manufacturing winding wires, cables and other electrical purposes.
Technical parameters of ПМТ, ПММ:
| Wire dimensions in width, mm | Tensile strength not less than, MPa | Relative elongation not less than, % |
|---|---|---|
| ПМТ | ПММ | |
| Up to 2, 5 and including | 310 | 35 |
| above 2,5 to 5,6 | 290 |